Solar Charge Controllers, Voltage Regulators
|
Morningstar's SunSaver™ Solar Charge Controller
6, 10 or 20 amps at 12 or 24 volts
This line of reliable wallmount PWM solar charge controllers by Morningstar are suited to small applications. Features clear pictograms for connections, internal temperature compensation and user selectable battery type. Available with built-in low voltage disconnect. 5 year warranty.
Product # |
Model |
Maximum Current |
Voltage |
Temperature Compensation |
Low Voltage Disconnect |
Metering |
|---|---|---|---|---|---|---|
04-27-006 |
SG 4 (not shown) |
4 |
12 |
Yes |
No |
No |
04-27-012 |
SS 6 |
6 |
12 |
Yes |
No |
No |
04-27-013 |
SS 6L |
6 |
12 |
Yes |
Yes |
No |
04-27-007 |
SS 10 |
10 |
12 |
Yes |
No |
No |
04-27-008 |
SS 10L |
10 |
12 |
Yes |
Yes |
No |
04-27-009 |
SS 10L 24 |
10 |
24 |
Yes |
Yes |
No |
04-27-010 |
SS 20L |
20 |
12 |
Yes |
Yes |
No |
04-27-011 |
SS 20L 24 |
20 |
24 |
Yes |
Yes |
No |
04-27-021 |
SSD-25-RM |
25 |
12 |
Yes |
Yes |
Yes |
| Morningstar - SunSaver Controller |
Morningstar's ProStar™ Solar Charge Controllers
15 & 30 amps at 12/24 or 48 volts
This all in one PWM solar charge controller from Morningstar will operate in temperatures from -40 to 85º C and features automatic equalization after deep discharges, (optional remote) temperature compensation, battery selector for charge voltage, and low battery load disconnect. Draws only 10 mA. The "M" series includes a digital display meter that shows charge and load currents as well as battery voltage. Five year warranty.
Product # |
Model |
Maximum Current |
Voltage |
Remote Temperature Compensation |
Low Voltage Disconnect |
Adjustable Voltage |
Metering |
|---|---|---|---|---|---|---|---|
04-27-002 |
PSTAR 15M |
15 |
12, 24 |
Option |
Yes |
Yes |
Yes |
04-27-004 |
PSTAR 30M |
30 |
12, 24 |
Option |
Yes |
Yes |
Yes |
| Morningstar -ProStar Series Controller |
Morningstar's TriStar™ Solar Charge Controllers
45 & 60 amps at 12-48 volts
Morningstar TriStar series is a PWM solar charge controller,
for either industrial or consumer applications,
that may be paralleled up to 300 A at 12, 24 or
48 V. Available in 45 and 60 A ratings it is a three function
controller that provides Solar or Load control or Diversion
regulation. PWM may be switched On or Off to minimize
RF noise. The controller is UL and CSA certified.
Five year warranty.
# 04-27-014 45 A
# 04-27-015 60 A
Options:
# 04-27-027 Metering option
# 04-27-028 Remote metering option
# 04-27-005 Remote temperature sensor, 10 meters
# 04-27-029 Relay Driver
# 04-27-031 MeterHub
![]() |
|
Product # |
Model |
Maximum |
Operating |
Low Voltage |
Adjustable |
|---|---|---|---|---|---|
(A) |
(V) |
(A) |
|||
04-16-004 |
C 35 |
35 |
12, 24 |
35 |
Yes |
04-16-005 |
C 40 |
40 |
12, 24, 48 |
40 |
Yes |
04-16-007 |
C 60 |
60 |
12, 24, 48 |
60 |
Yes |
CM & CM/ R Meter
Designed for use with C Series solar charge controllers, the
CM digital meter mounts onto the front of the charge
controller or can be installed up to 100' (31 m) away. It
displays volts, amps, and resettable cumulative amp
hours for a solar array, DC loads, or diversion loads,
depending on application. The CM/R comes with 50'
(15 m) or 100' (31 m) communication cable for remote
installation.
# 04-16-009 Digital display
# 04-16-010 Remote display (50 or 100 ft cable, specify)
This rugged and versatile unit is used to power a small
load at 12 V from a 24 V system, or to power a small 24 V
load from a 12 V system. Functions two ways, producing
12 V @ 20 A from a 24 V input or can be connected
backwards to produce 24 V @ 10 A from a 12 V input.
# 04-25-001 12 - 24 V, 20 A
# 04-25-002 12 - 24 V, 50 A
# 04-25-003 24 - 48 V, 10 A
Morningstar's Sunsaver MPPT Solar Charge Controller
15 amps at 12 or 24 volts
With a peak conversion efficiency of over
97 % and excellent performance in low
insolation levels, this MPPT solar charge controller is ideal for smaller
12 or 24 V PV systems up to 400 W and 75 Voc.
Features include electronic protection against:
• PV: Overload, Short Circuit, High Voltage
• Load: Overload, Short Circuit
• Reverse Polarity: Battery, PV and Load
• Lightning and Transient Surges
• Reverse Current at Night
# 04-27-022 15 A MPPT Solar Charge Controller
Options:
# 04-27-023 PC MeterBus Adaptor, light controller
# 04-27-024 Remote Meter - may be used with MPPT, Sunsaver Duo
or SureSine inverter
# 04-27-005 Remote Temperature Sensor
| Morningstar - SunSaver MPPT Controller |
Morningstar TriStar MPPT™ Solar Controller with TrakStar™45 or 60 amps at up to 150 volts open circuit
The 45 and 60 A TriStar MPPT solar charge controllers provide the industry's highest peak efficiency of 99 %. This extremely reliable controller can be used with battery systems from 12 VDC to 48 VDC with a PV open circuit voltage of up to 150 Voc and when used with the optional TriStar meter or remote meter you can log up to 200 days of data. The maximum self-consumption of this unit is 4 watts and comes equipped with a temperature sensor. CE compliant.
# 04-27-025 45 A
# 04-27-026 60 A
Options:
# 04-27-027 Digital Meter
# 04-27-028 Remote Digital Meter
# 04-27-029 Relay Driver
| Morningstar -TriStar MPPT Controller |
OutBack FM60 and FM80 MPPT Charge Controller
These Maximum Power Point Tracking charge
controllers enable your PV system to achieve its
highest possible performance. They permit the
use of a higher output voltage PV array with a lower
battery voltage - such as charging a 24 VDC battery with a
48 VDC PV array. This reduces wire size and power loss
from the PV array to the battery location while maximizing
the system's performance. Rated for up to 80 A of DC
output current, they can be used with battery systems
from 12 to 60 VDC with a PV open circuit voltage as
high as 150 Voc. The set points are fully adjustable to
allow use with virtually any battery type, chemistry, and
charging profile. The OutBack FM60 and FM80 come
standard with an easy to use and understand display. The
four line, 80 character, backlit LCD display is used for
programming and monitoring of the system's operation
including built-in data logging with 64 days of memory.
# 04-53-038 Controller, 60 A, 150 VDC
# 04-53-037 Controller, 80 A, 150 VDC
Options:
# 08-53-042 Remote temperature sensor
# 08-53-153 Mounting support
Xantrex MPPT Charge Controller
The Xantrex XW Solar Charge Controller tracks the
electrical maximum power point of a PV array to deliver
the maximum available current for charging batteries.
The XW Solar Charge Controller can be used with 12, 24,
36, 48, and 60-volt DC battery systems and is able to charge
a lower nominal-voltage battery from a higher nominalvoltage
array. The XW Solar Charge Controller can be
installed in single or multi-unit configurations with a
Xantrex XW Hybrid Inverter/ Charger or can be used in
other solar energy systems where a solar charge
controller is needed.
# 04-16-011 60 A MPPT Controller
# 04-16-006 80 A MPPT Controller
Product features:
. Convection-cooled design does not require a cooling fan
. Selectable two or three stage charging algorithms with manual
equalize
. Configurable auxiliary output
. Input over-voltage and under-voltage protection, output overcurrent
protection, and backfeed
. Reverse current protection, over-temperature protection and
power derating when output power and ambient temperature
are high
. Battery Temperature Sensor (BTS) included
. XanbusT-enabled network communications
. Five-year warranty (10 year warranty optional)
![]() |
![]() |
MidNite Solar's Classic 150, 200 and 250 VDC MPPT Charge Controllers |
The MidNite Solar Classic 150, 200 and 250 VDC input. The MPPT Charge Controller will substantially increase the flexibility, features and range currently found on MPPT controllers. The Classic MPPT Charge Controller is the only MPPT controller that has Arc Fault Detection, making this controller the safest controller available. With the Classic ranging up to 96 amps, why would you need any other controller? |
||
Product features:
* 150, 200 and 250 VDC input
* 12-72V battery charging standard with models up to 120V battery bank
* Built in DC-GFP and Arc Fault Detector
* Solar, wind and hydro MPPT modes
* Set up Wizard with voice help screens English, Spanish and French
* Wizard walks you through:
- Battery hook up
- PV array sizing and hook up
- Solar, Wind turbine and Hydro program selection
- Wire sizing in AWG and Metric
- Breaker selection
- PV combiner selection
- Sunrise and sunset program set up
- Voltage drop calculations
* Ethernet, USB and RS232
* Remote and local displays possible
* 32 megs of data logging
Model |
Classic150 04-77-001 |
Classic200 04-77-002 |
Classic 250 04-77-003 |
|---|---|---|---|
Operating volts in |
150 VDC |
200 VDC |
250 VDC |
Max HyperVOC |
150+battery |
200+battery |
250+battery |
Bat charge V |
12 - 93 |
12 - 93 |
12 - 93 |
Max current out 96 amps |
79 amps |
63 amps |
40 amps |
Environment |
40 - 40° C |
||
Dimensions of Classic |
14.87" x 5.95" x 4.00" 378 mm x 151 mm x 102 mm |
||
Dimensions boxed |
19.0" x 8.5" x 5.7" 483 mm x 216 mm x 145 mm |
||
Power Rating
The lines on the graph represent the MidNIte Solar Classic Charge Controller output current at different Max Power Points Voltage (not VOC). To estimate the Max Power Point of your system; first you have to find out the VOC of the Photovoltaic strings connected to the Classic. For example If 5 Modules in series in one string and STC VOC rating is 36.6V, then the VOC of the string equals: 5(modules) * 36.6v(STC VOC) = 183V.
The rule of thumb says that the MPP will be around 80% of the string's VOC; 183v * 0.8 = 146.4v On the graph of the Classic model you have, the X axis represents the Battery Voltage and the Y axis is the Output current. Knowing that, go to the corresponding graph and look for the a line close to your system's MPP voltage and you can then determine the max output power for your system design.

|
![]() |
||||||||||||
MNPV12-250 (enclosure only)
| ![]() |
||||||||||||
MNEPV20
|
![]() |
||||||||||||
![]() |
Solar Boost MPPT Charge Controller
Patented Maximum Power Point Tracking technology allows Solar Boost 2512i-HV, 1524iXand 2000E to increase charge current up to 30%or more compared to conventional charge controllers. |
![]() |
![]() |
![]() |
# 04-63-018 |
# 04-63-001 |
# 04-63-017 |
shown with optional solar mount box |
Product # |
Model |
Battery Voltage |
Maximum PV Voc @ STC (1) |
Max. PV Power @ Vbat/ Vpv (2) |
Max. Output Current |
Charge Algorithm |
Load Control |
Lighting Control |
|
|---|---|---|---|---|---|---|---|---|---|
(A) |
(V) |
(A) |
(A) |
||||||
04-63-001 |
SB2000E |
12 |
24.0 |
340 |
12/ 12 |
25 |
2-stage, plus Equalization |
No |
No |
04-63-017 |
SB1524iX |
12/ 24 |
45.6 |
270 200 400 |
12/ 12 12/ 20 12/ 24 24/ 24 |
20 15 15 15 |
3-stage, plus Equalization |
Yes |
20A/ 15A Voltage or AH based |
04-63-018 |
SB2512i-HV |
12 |
40.0 |
370 270 |
12/ 12 12/20 |
25 20 |
3-stage |
No |
No |
1. PV VOC at STC should not exceed controller maximum PV input voltage rating ÷1.25. Values
shown here already include 1.25 derating.
2.12V PV refers to typical 36 cell module providing VMP/VOC of ~18V/22V at STC. 20V PV refers
to 60 cell module (?30V/37V), and 24V PV refers to 72 cell module (~35V/44V).
| Solar Boost 2512i-HV & 2512iX-HV |
| Solar Boost 2000E |
Options :
# 04-63-004 IPN Pro-Remote w/500 A Shunt
# 04-63-005 IPN Pro Remote only
# 04-63-006 IPN Remote only
# 04-63-012 Wall Mount Box for SB2000E (# 04-63-001)
# 04-63-013 Battery Temperature Sensor, 20 ft
# 04-63-019 Wall Mount Box for SB2512 (# 04-63-018) or SB1524iX (# 04-63-017)
| Matrix Energy Inc. | info@matrixenergy.ca | Toll Free: 1-866-630-5630 |