Off-Grid Inverters
![]() |
OutBack inverters offer a list of innovations versus competing products.
With improved inverter reliability using next generation power technology, they also make their inverters modular so systems could be stacked in any configuration and are easily expanded to build systems up to 36 kW of total power. Best of all most models are now grid-tie capable. |
OutBack products offer unique features including:
| • Smaller design takes less wall space • Fully sealed (FX and GTFX models) or bug-proof (GVFX) • Grid tie compatible without additional accessories • True pure sine wave output instead of 34 steps per cycle offers lower harmonic distortion • Better able to start large motor loads • Higher efficiency, especially at higher power loads • Built-in generator start software • Field serviceable with end user board swaps • Stackable in series/parallel for 120/ 240 VAC and 3 phase, up to 36 kW |
![]() |
OutBack offers fully sealed models in both 24 and 48 V, with 500 watts more power than the original FX series. With an all-aluminum chassis, conformal coated circuit boards and a gasketed design, the inverter is fully protected from some of the major causes of inverter failure: corrosion and insects.
The modular design allows OutBack Inverters to be stacked in either series (120 VAC) or parallel (120/ 240 VAC), or even three phase (120/ 208 VAC) and up to 8 inverters may be stacked in a single system. OutBack inverters can be used for on grid or off-grid renewable energy systems, back-up power and vehicle applications.
Dimensions: 41.4 x 21.1 x 29.2 cm / 16.25 x 8.25 x 11.5" high.
Weight 27 kg / 62 lbs.
Five year warranty.
* 50 Hz models available.
Product |
Model |
Sealed or vented |
Grid tied ready |
Continuous Power |
DC voltage |
Overload capability |
DC charge rate |
|---|---|---|---|---|---|---|---|
(W) |
(W) |
(V) |
(A) |
||||
08-53-010 |
FX2012 |
sealed |
no |
2000 |
4000 |
12 |
80 |
08-53-152 |
FX2524T |
sealed |
no |
2500 |
6000 |
24 |
55 |
08-53-026 |
GVFX3524 |
vented |
yes |
3500 |
5000 |
24 |
85 |
08-53-027 |
GVFX3648 |
vented |
yes |
3600 |
5000 |
48 |
45 |
08-53-141 |
VFX2812 |
vented |
no |
2800 |
4800 |
12 |
125 |
08-53-037 |
VFX3524 |
vented |
no |
3500 |
6000 |
24 |
85 |
08-53-038 |
VFX3648 |
vented |
no |
3600 |
6000 |
48 |
45 |
![]() |
Tight space? E-Panels are the ideal solution. |
All E-Panels come standard with the AC bypass and AC input disconnect pre-wired, din rails for 6 additional 13 mm wide AC or DC breakers, battery breaker installed with inverter plus and minus cables, 500 amp/ 50 mV shunt, battery plus busbar, battery minus busbar, AC busbars allowing up to 14 connections per circuit, ground busbar, DC cover, AC flex conduit tubing with couplers, FM60/ Classic mounting bracket (for OutBack models only) grommets and bushings, numerous knock outs for cable entry and exit, lots of hardware for mounting inverter, charge controller etc, wall mounting brackets, installation instructions, wiring diagram mounted on the door, and a tech support phone number.
OutBack Inverter E-Panels
OutBack Inverter E-Panel options: Remote
temperature sensor RTS1, charge controllers FM60 or FM801, lightning arrestors LA302AC and LA302DC1, remote system control black oval with 50' cable MATE_B1, surge protector FW-SP-ACA1, crate1, additional AC and DC load breakers2, pairs
of ten feet 4/0 CSA inverter cable or non CSA2, four port communication manager works with inverter and FLEXmax controller HUB-42, FLEXnet- DC2 (shunt not included), 500 A - 50 mV shunt2 to be used with FLEXnet-DC (maximum of 3 units).
Notes : 1- Factory installed item when requested (additional cost applied)
2- Item installed on the site Charge controllers are installed with either two 60 A breakers with the FM60 or two 80 A breakers with FM80 controllers.
Product |
# Model |
Continuous Power |
Surge Capacity |
Input Voltage |
Charger |
Dimensions L x W x H |
Weight |
Grid tie ready |
|---|---|---|---|---|---|---|---|---|
(W) |
(W) |
(V) |
(A) |
(cm) |
(kgs) |
|||
08-49-007 |
2.0 kW, 12 V OutBack E-Panel |
2000 |
4000 |
12 |
80 |
48.0 x 44.0 x 71.0 |
52 |
no |
08-49-008 |
2.5 kW, 24 V OutBack E-Panel |
2500 |
4800 |
24 |
55 |
48.0 x 44.0 x 71.0 |
52 |
no |
08-49-009 |
2.8 kW, 12 V OutBack E-Panel |
2800 |
4000 |
12 |
125 |
48.0 x 44.0 x 71.0 |
52 |
no |
08-49-010 |
3.6 kW, 48 V OutBack E-Panel |
3600 |
5000 |
48 |
45 |
48.0 x 44.0 x 71.0 |
55 |
no |
08-49-011 |
3.5 kW, 24 V OutBack E-Panel |
3500 |
5000 |
24 |
85 |
48.0 x 44.0 x 71.0 |
55 |
no |
08-49-012 |
2.5 kW, 24 V, OutBack G-T, E-Panel |
2500 |
4800 |
24 |
55 |
48.0 x 44.0 x 71.0 |
52 |
yes |
08-49-013 |
3.5 kW, 24 V, OutBack G-T, E-Panel |
3500 |
5000 |
24 |
85 |
48.0 x 44.0 x 71.0 |
55 |
yes |
TR inverter E-Panels
A Schneider Electric "TR" inverter E-Panel includes: TR inverter
mounted on the left hand hinged door, remote temperature sensor,
internal inverter cables, PV+busbar, battery+ busbar, 50 A AC
input/ output bypass, 50 A AC input
disconnect, 250 A inverter battery
breaker, AC busbars, covers for DC and
AC end, wall mounting brackets and
hardware. AC breakers are rated at
277 VAC.
Product |
Model |
Continuous Power |
Surge Capacity |
Input Voltage |
Charger |
Dimensions L x W x H |
Weight |
|---|---|---|---|---|---|---|---|
(W) |
(W) |
(V) |
(A) |
(cm) |
(kgs) |
||
08-49-018 |
1.5 kW, 12 V TR E-Panel |
1500 |
3000 |
12 |
70 |
48.0 x 44.0 x 71.0 |
40 |
08-49-019 |
1.5 kW, 24 V TR E-Panel |
1500 |
3000 |
24 |
35 |
48.0 x 44.0 x 71.0 |
40 |
08-49-020 |
2.4 kW, 12 V TR E-Panel |
2400 |
4800 |
12 |
120 |
48.0 x 44.0 x 71.0 |
45 |
08-49-021 |
2.4 kW, 24 V TR E-Panel |
2400 |
4800 |
24 |
70 |
48.0 x 44.0 x 71.0 |
42 |
08-49-022 |
3.6 kW, 24 V TR E-Panel |
3600 |
7200 |
24 |
70 |
48.0 x 44.0 x 71.0 |
45 |
OutBack PowerBoards
The installation of a PowerBoard is simple and
fast. Just screw the PowerBoard to a wall near
the batteries, connect the AC output to your breaker panel, the AC
input to your generator, and the DC input to the battery bank.
Matrix OutBack PowerBoards combine the inverter (s), safety
disconnects, circuit breakers, metering and solar array controller on
one prewired aluminum back-plate that's ready for an immediate,
code approved installation.
Items included on a PowerBoard: The inverter, the
FW-250-1000-DC, the FW-250-1000-AC, the bypass switch
FW-IOB-DUAL, the internal inverter cable, the mounting plate
FWMP for up to two inverters, the AC/ DC conduit, all the
terminal bus bar (for AC, DC, negative and ground), and HUB-4
if there is two inverters. (PowerBoards are non-refundable.)
OutBack PowerBoard options: Remote temperature sensor RTS1,
charge controllers FM60 or FM801, mounting support for one
charge controller1, lightning arrestors LA302AC and LA302DC1,
MATE_B1, remote system control black oval with 50' cable
MATE_B1, surge protector FW-SP-ACA1, crate1, auto transformer
FW-X2401, CSA approval available or field inspection SPE-10001,
additional DIN rail AC and panel mounted DC load breakers2,
pairs of ten feet 4/0 CSA inverter cable or non CSA2, four port
communication manager works with inverter and FLEXmax
controller HUB-42, FLEXnet- DC monitor FLEXnet- DC2 (shunt
not included), 500 amp- 50 mV shunt2 to be used with
FLEXnet-DC (maximum of 3 units).
# 03-49-008 CSA approved
Notes:
1- Factory installed item when requested (additional cost applied)
2- Item installed on the site
Charge controllers are installed with either two 60 A breakers with
the FM60 or two 80 A breakers with FM80 controllers.
Product # |
Model |
Continuous Power |
Surge Capacity |
Input Voltage |
Output Voltage |
Charger |
Dimensions L x W x D |
Weight |
|---|---|---|---|---|---|---|---|---|
(W) |
(W) |
(V) |
(VAC) |
(A) |
(cm) |
(kgs) |
||
08-49-001 |
PB-FX2524T |
2500 |
4800 |
24 |
120 |
55 |
120.0 x 52.0 x 35.0 |
90 |
08-49-002 |
PB-FX2524T2 |
5000 |
9600 |
24 |
120 |
110 |
120.0 x 52.0 x 35.0 |
140 |
08-49-003 |
PB-VFX3524 |
3500 |
5000 |
24 |
120 |
85 |
120.0 x 52.0 x 35.0 |
90 |
08-49-004; |
PB-VFX3524T2x2 |
7000 |
1000 |
24 |
120 |
170 |
120.0 x 52.0 x 35.0 |
140 |
08-49-005 |
PB-VFX3648 |
3600 |
5000 |
48 |
120 |
45 |
120.0 x 52.0 x 35.0 |
90 |
08-49-006 |
PB-VFX3648x2 |
7200 |
10000 |
48 |
120 |
90 |
120.0 x 52.0 x 35.0 |
140 |
| OutBack Options | ||
|---|---|---|
Product # |
Model |
Description |
08-53-032 |
Mate-B |
System control and display for OutBack inverter and charge controller, black |
08-53-154 |
FN-DC |
Flexnet DC battery monitor, see your system's condition/ performance- historical data up to 128 days |
08-53-029 |
Hub4 |
Communication manager allows the Mate to control & monitor a max. of 4 OutBack products |
08-53-028 |
Hub10 |
|
08-53-042 |
RTS |
Remote temperature sensor 15' (5m) |
08-53-155 |
PSX-240 |
Auto-transformer with enclosure |
08-53-122 |
PSPV |
PV Combiner Enclosure - holds up to 12 OBB breakers or 8 fuse holders (use with 08-53-094 10 amps or 08-53-095 15 amps) |
| OutBack FLEXware 250 section | ||
08-53-148 |
FW250 |
DC and/or AC breaker enclosure for one inverter/ charger, holds up to 8 breakers, 1 for 175-250 A, & GFCI AC outlet |
08-53-053 |
FW-IOB-S-120VAC |
AC in/out/bypass breaker kit, 60 A 120 VAC for FW250 |
08-53-157 |
FW-SP-250 |
Flexware surge protector- Transient over voltage suppression for FX series inverter/chargers- for use in Flexware 250 |
08-53-163 |
FW-Shunt250 |
500 amp 50 mV DC current shunt with attached terminal bus |
| OutBack FLEXware 500 section | ||
08-53-020 |
FW-ACA |
AC conduit adapter (for FW500 and FW 1000) |
08-53-021 |
FW-DCA |
DC conduit adapter (for FW500 and FW 1000) |
08-53-146 |
FW-X240 |
4 kVA 120/240 auto-transformer for 240 V loads to be housed within the Flexware 500 or 1000 |
08-53-108 |
FW500-DC |
DC Breaker enclosure for 1-2 FX Inverters, holds up to eight DC breakers, 2 175-250A, FW-DCA required |
08-53-149 |
FW500-AC |
AC Breaker enclosure for 1or 2 FX inverters, up to 16 AC breakers, FW-ACA required |
08-53-053 |
FW-IOB-D-120VAC |
AC in/out/bypass breaker kit for FW500,1 Ph,60 A 120 VAC |
08-53-054 |
FW-IOB-D-120/240VAC |
AC in/out/bypass breaker kit assembly for FW500 split phase, 60 A 120/240 VAC |
08-53-039 |
FW-MP |
Powder coated mounting plate (1 for FW500, 2 for FW1000) |
08-53-158 |
FW-SP-ACA |
Flexware surge protector- Transient over voltage suppression for FX series inverter/chargers- for use in Flexware ACA (for FW500 & FW1000) |
| OutBack FLEXware 1000 section | ||
08-53-150 |
FW1000-DC |
DC breaker enclosure for up to 4 FX inverters.Holds up to 11 DC breakers,1-6 175-250 A, FW-DCA required |
08-53-151 |
FW1000-AC |
AC Breaker enclosure for up to 4 FX inverters, up to 32 AC breakers, FW- ACA required |
08-53-161 |
FW-IOB-T-120/208VAC |
AC in/out/bypass breaker kit assembly for FW1000 3-phase, 60A 120/208VAC |
08-53-162 |
FW-IOB-Q-120/240VAC |
AC in/out/bypass breaker kit assembly for FW1000 split phase, 60 A 120/240 VAC |
| OutBack Breakers | ||
08-53-061 |
OBB-15-120VAC-DIN |
AC breaker - 15 amp 120 VAC OutBack - 0.50" wide |
08-53-063 |
OBB-20-120VAC-DIN |
AC breaker - 20 amp 120 VAC OutBack - 0.50" wide |
08-53-067 |
OBB-30D-480VAC-DIN |
AC breaker - 30Amp 480 VAC OutBack - 1.0" wide |
08-53-069 |
OBB-50T-480VAC-DIN |
AC breaker - 50 amp 480 VAC 3 ph uses 3 spaces 1.5" wide |
08-53-075 |
OBB-10-150VDC120VAC-PNL |
DC breaker - 10 amp 150 VDC small size - 0.75" wide |
08-53-076 |
OBB-100-125VDC-PNL |
DC breaker - 100 amp 125 VDC medium size - 1.0" wide |
08-53-078 |
OBB-15-150VDC120VAC-PNL |
DC breaker - 15 amp 150 VDC small size - 0.75" wide |
08-53-095 |
OBB-15-150-VDC-DIN |
15 A PV breaker |
08-53-079 |
OBB-175-125VDC-PNL |
175 A breaker |
08-53-081 |
OBB-250-125VDC-PNL |
250 A breaker |
08-53-094 |
OBB-10-150-VDC-DIN |
10 A PV breaker |
08-53-X06 |
OBB-20-150VDC-DIN |
20 A PV breaker |
08-53-X05 |
OBB-60-277VAC DIN |
AC breaker - 60 amp 120 and 277VAC - 0.50" wide |
![]() |
A Schneider Electric - Xantrex inverter/charger is a combination of an inverter, battery charger and transfer switch into one complete system. Xantrex inverter/ chargers are available in different sizes and power ranges to suit just about any application. |
XW Series
The XW Hybrid Inverter/ Charger (XW) is a true sine wave,
120/ 240-volt AC, split-phase inverter, integrating the
best features available in the market, the XW Hybrid
Inverter/ Charger's design makes installation quicker
and easier. It is the foundation for battery- based
residential and commercial applications up to 18
kilowatts (kW). Capable of being grid-interactive (to sell
excess back to the grid) or grid-independent, the XW can operate
with generators and renewable energy sources to provide full time
or backup power.
These full function programmable sine wave inverter/chargers
make operating on-grid, off-grid or generator back-up electrical
systems easier. Certified to UL1741 and CSA C22.2 N0. 107.1-01
. True sine wave output
. 120/ 240 volt AC spilt phase operation
. Dual AC inputs
. Capability to work with two-wire and three-wire generator
starting systems
. Integrated design to minimize external balance-of-system
components
. XanBus™ enabled network communication
. Unprecedented surge capacity
. Efficient, power factor corrected, high-current, multistage battery
charging
. Stackable for 208 3 PH operation
Options:
# 08-16-183 XW Power Distribution Panel
# 08-77-003 MNE250XW Power Distribution Panel
# 08-16-184 XW Connection Kit for Second Inverter
# 08-16-185 XW Conduit Box
# 04-16-011 XW MPPT Solar Charge Controller
# 08-16-187 XW System Control Panel
# 08-16-188 XW Automatic Generator Start
To install a third inverter a conduit box, a longer cable and a
longer CAT5 cable are required (customizable).
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
# 08-77-003 |
# 08-16-184 |
# 08-16-185 |
# 08-16-001 |
# 08-16-187 |
# 08-16-188 |
Product # |
Model |
Continuous Power (W) |
Surge Capacity (Arms) |
Input Voltage (V) |
AC Input and Output Voltage (V) |
Dimensions L x W x H (cm) |
Weight (kgs) |
|---|---|---|---|---|---|---|---|
08-16-180 |
XW6048-120/240-60 |
6000 |
L -N : 105 L -L : 52.5 |
48 |
120 / 240 |
23.0 x 41.0 x 58.0 |
56 |
08-16-181 |
XW4548-120/240-60 |
4500 |
L -N : 75 L -L : 40 |
48 |
120 / 240 |
23.0 x 41.0 x 58.0 |
54 |
08-16-182 |
XW4024-120/240-60 |
4000 |
L -N : 70 L -L : 35 |
24 |
120 / 240 |
23.0 x 41.0 x 58.0 |
53 |
TR series
Midsize, cost-effective, modified sine wave
inverters for most everyday uses. TR series
inverters set a new standard for "entry-level"
inverter/chargers. By converting 12 or 24-volt
power to clean AC with high surge capacities,
they can run most common tools and appliances. |
![]() |
Features:
. Easy to use controls for battery type and capacity,
maximum charge rate, low voltage disconnect.
. All inverters are UL 1741 and CSA 22.2
No 107.1 Standards.
. 50Hz available
Options:
# 08-16-202 TR- Conduit Box
# 08-16-203 TR-Remote On/ Off Switch
# 08-16-204 TR1512, 1.5 kW, 12 VDC Inverter/ Charger, 230 V, 50 Hz
# 08-16-205 TR1524, 1.5 kW, 12 VDC Inverter/ Charger, 230 V, 50 Hz
# 08-16-206 TR2424, 2.4 kW, 12 VDC Inverter/ Charger, 230 V, 50 Hz
Product |
Model |
Cont. Power (W) |
Surge Capac. (W) |
Input Volt. (VDC) |
Output Volt. (VAC) |
Charger |
Dimensions L x W x H (cm) |
Weight (kgs) |
|---|---|---|---|---|---|---|---|---|
08-16-197 |
TR1512 |
1500 |
3300 |
12 |
120 |
70 |
21.6 x 18.4 x 54.6 |
17.7 |
08-16-198 |
TR1524 |
1500 |
4800 |
24 |
120 |
35 |
21.6 x 18.4 x 54.6 |
17.7 |
08-16-199 |
TR2412 |
2400 |
6200 |
12 |
120 |
120 |
21.6 x 18.4 x 54.6 |
23.2 |
08-16-200 |
TR2424 |
2400 |
8600 |
24 |
120 |
70 |
21.6 x 18.4 x 54.6 |
18 |
08-16-201 |
TR3624 |
3600 |
12000 |
24 |
120 |
70 |
21.6 x 18.4 x 54.6 |
23.6 |
Inverters-Xantrex Trace Series InverterCharger
T240 Transformer
| The T240 is a 4.5 kVA transformer providing 240 VAC from a single inverter. The transformer can step up from 120 VAC to 240 VAC or the reverse - turning 240 VAC into 120 VAC allowing the full output of a 240 VAC generator to be used by 120 VAC appliances. The T240 can also be used as balancing transformer allowing a single 120 VAC inverter to be connected to a generator which has 240 VAC output. The T240 features knockouts for conduit connections, two pole 25 A circuit breaker/ disconnect and a two year warranty. | ![]() |
# 08-16-135
TR inverter E-Panels
A Schneider Electric "TR" inverter E-Panel includes: TR inverter
mounted on the left hand hinged door, remote temperature sensor,
internal inverter cables, PV+busbar, battery+ busbar, 50 A AC
input/ output bypass, 50 A AC input
disconnect, 250 A inverter battery
breaker, AC busbars, covers for DC and
AC end, wall mounting brackets and
hardware. AC breakers are rated at
277 VAC.
Product # |
Model
| Continuous Power |
Surge Capacity |
Input Voltage |
Charger |
Dimensions L x W x H |
Weight |
|---|---|---|---|---|---|---|---|
(W) |
(W) |
(V) |
(A) |
(cm) |
(kgs) |
||
08-49-018 |
1.5 kW, 12 V TR E-Panel |
1500 |
3000 |
12 |
70 |
48.0 x 44.0 x 71.0 |
40 |
08-49-019 |
1.5 kW, 24 V TR E-Panel |
1500 |
3000 |
24 |
35 |
48.0 x 44.0 x 71.0 |
40 |
08-49-020; |
2.4 kW, 12 V TR E-Panel |
2400 |
4800 |
12 |
120 |
48.0 x 44.0 x 71.0; |
45 |
08-49-021 |
2.4 kW, 24 V TR E-Panel; |
2400 |
4800 |
24 |
70 |
48.0 x 44.0 x 71.0 |
42 |
08-49-022 |
3.6 kW, 24 V TR E-Panel; |
3600 |
7200 |
24 |
70 |
48.0 x 44.0 x 71.0 |
45 |
![]() |
Magnum Energy is a leading manufacturer of premium inverter/chargers for Mobile and Renewable Energy applications. |
| MS series A new pure sine wave inverter designed specifically for the most demanding mobile and off grid applications. The MS Series is powerful, easy-to-use, and best of all, cost effective. Install in four easy steps: simply connect the MS inverter's output to your distribution circuits or electrical panel, connect your shore power cable (AC) to the inverter's easy-to-reach terminal block, connect the batteries, and switch on the power. The MS Series is ETL listed to the stringent requirements of UL / cUL 458 for mobile use and UL 1741 for off grid installations. |
![]() |
The MS-PAE series
The unique design of the MS-PAE Series can provide both 120 and 240 volt output simultaneously from one unit thus eliminating the
need to stack two units to obtain a 240 volt AC output. The new MS4024PAE and MS4448PAE use 120/240 split phase input/ output
and have continuous output rating of 4000 watts and 4400 watts respectively. The MS4024PAE and MS4448PAE include a 105 and
60 Amp PFC (Power Factor Corrected) Charger and is ETL listed to the stringent requirements of UL1741 and certified to CSA
C22.2 NO.107.1-01 for Renewable Energy installations.
Options:
# 08-80-006 Inverter/ Charger Remote w/ 25 ft Cable
# 08-80-007 Automatic Generator Start, 3 Relay, Stand Alone
# 08-80-008 Battery Monitor Kit w/ Shunt
# 08-80-009 Digital LCD Display Remote w/ 50 ft Cable
# 08-80-010 Automatic Generator Start, 3 Relay, Network
# 08-80-011 AC/ DC Conduit Box, White
# 08-80-012 3 LED Remote w/ 25' Cable, MM Inverter only
# 08-80-013 DC Load Disconnect, Pigtail Adapter
# 08-80-014 Magnum Panel, Hood only
# 08-80-015 Magweb Web Based Monitoring Kit - wireless
# 08-80-016 Magweb Web Based Monitoring Kit - Ehternet
Product |
Model |
Continous Power |
Surge capacity |
DC Input Voltage |
Charger |
AC input & output |
Dimensions L x W x H |
Weight |
|---|---|---|---|---|---|---|---|---|
(W) |
(W) |
(V) |
(A) |
(V) |
(cm) |
(kgs) |
||
08-80-001 |
MS2012 |
2000 |
3300 |
12 |
100 |
120 |
35.0 x 32.0 x 20.3 |
21.3 |
08-80-002 |
MS2812 |
2800 |
3900 |
12 |
125 |
120 |
35.0 x 32.0 x 20.3 |
27.2 |
08-80-003 |
MS4024 |
4000 |
5800 |
24 |
105 |
120 |
35.0 x 32.0 x 20.3 |
27.2 |
08-80-004 |
MS4024PAE |
4000 |
5800 |
24 |
105 |
120/240 |
35.0 x 32.0 x 20.3 |
26.3 |
08-80-005 |
MS4448PAE |
4400 |
8500 |
48 |
60 |
120/240 |
35.0 x 32.0 x 20.3 |
26.3 |
Stacking Magnum Inverters
Magnum “MS Series” inverters are stackable providing up to 17.6 KVA of continuous power. Panels can be configured to accommodate from one to four inverters with two separate enclosures for AC and DC connections. These white powder-coated panels include main DC and AC breaker, DC shunt, and inverter AC input protection.
Product # |
Model # |
Description |
|---|---|---|
08-80-018 |
ME-RTR |
Magnum Router (Req'd for Parallel Stacking of the MS-PAE Models, incl 2 Stacking Cables) |
08-80-019 |
MPSL-30D |
Single LP Enclosure w/ 30 A Dual Pole AC Input Breaker for 2 Inverters |
08-80-020 |
MPSH-30D |
Single HP Enclosure w/ 30 A Dual Pole AC Input Breaker for 3 Inverters |
08-80-021 |
MPDH-30D |
Dual Hp Enclosure w/ 30 A Dual Pole AC Input Breaker for 4 Inverters |
08-80-022 |
MPXD-30D-L |
Extension Box, MPSL Left Side (includes DC/ AC Breaker and Wires, MP-HOOD, Parallel Cables) |
08-80-023 |
MPXD-30D-R |
Extension Box, MPSL Right Side (includes DC/ AC Breaker and Wires, MP-HOOD, Parallel Cables) |
08-80-024 |
BP-S |
Backplate Single (Fits 1-MPSL, 1-MPSH or 1-MPX) |
08-80-025 |
BP-D |
Backplate Double (Fits 1-MPDH; 1-MPSL or 1-MPSH and 1-MPX) |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
# 08-80-019 |
# 08-80-020 |
# 08-80-021 |
# 08-80-022 |
$ 08-80-024 |
$ 08-80-025 |
Magnum Inverter E-Panels |
![]() |
![]() |
E-Panels are compact, affordable and professional panels for mounting a single inverter. All E-Panels come wired with 6 AWG wire for all AC circuits. The main features are it's small size and low cost. |
E-Panels come standard all pre-wired with the AC bypass and AC input disconnect, din rails for 6 additional 13 mm wide AC or DC breakers, main battery breaker installed, internal inverter plus and minus cables, 500 amp/ 50 mV shunt, battery plus busbar, battery minus busbar, AC busbars allowing up to 14 connections per circuit, ground busbar, DC cover, AC flex conduit tubing with couplers1, grommets and bushings1, PV plus busbar 2, FLEXmax charge controller mounting bracket for installation on the right side, numerous knock outs for cable entry and exit, lots of hardware for mounting inverter, wall mounting brackets, installation instructions, wiring diagram mounted on the door, and a tech support phone number. These standard enclosures come as left hand hinged. On the E-Panel the inverter is mounted on the hinged door except the XW series inverters which are mounted on the top of their respective E-Panel. We offer complete packaged systems with the inverter already pre-wired except the XW series inverters.
Product # |
Model |
Description |
Dimensions
L x W x H (cm) | Weight
(kgs) |
|---|---|---|---|---|
08-77-001 |
MNE175DR/TR-L |
E-Panel, Schneider Electric DR & TR series, lh, grey steel |
68.0 x 24.0 x 9.2 |
16 |
08-77-002 |
MNE250ST |
E-Panel, all OutBack series, lh, grey steel |
66.0 x 24.0 x 9.2 |
16 |
08-77-003 |
MNE250XW |
E-Panel, Schneider electric XW series, lh, grey steel |
46.0 x 44.5 x 22.0 |
22 |
08-77-004 |
MNE250ALM-L |
E-Panel, magnum, all MS series, white Alum |
64.0 x 37.0 x 9.2 |
16 |
08-77-005 |
MNE250STM-L-240 |
E-Panel, magnum, all MS-AE series, white steel |
64.0 x 37.0 x 11 |
20 |
08-77-006 |
MNE250DR/TR-L |
E-Panel, Schneider Electric DR & TR series, lh, grey steel |
68.0 x 24.0 x 9.2 |
16 |
![]() |
![]() |
![]() |
![]() |
# 08-77-001 |
# 08-77-002 |
# 08-77-003 |
# 08-77-005 |
lh= left hand
Notes: 1- For OutBack inverter only. 2- Not included in the E-Panel for OutBack inverter (available if requested).
Inverter By-Pass Switches
Inverter By-Pass Switches allow you to select which
source of power connects to your AC distribution
panel. Typical installations have either generator
or inverter inputs. Interlocked breakers ensure that
only one source is connected at a time. Ideal as a
manual isolation switch to bypass the inverter.
Over current protected.
# 08-17-002 30 A transfer switch
# 08-17-003 60 A transfer switch
DC Disconnects
The electrical code requires that inverters be installed
with a battery circuit breaker. These powder coated
enclosures include the main DC disconnect, din rail for up
to five additional DC breakers, grounded bus and 5/16"
bonding battery minus stud.
Measures 25 x 13 x 46 cm, 3.2 kgs.
Product # |
Model | Description |
|---|---|---|
03-77-006 |
MNDC125 | 125 A DC Disconnect, Din Rail |
03-77-007 |
MNDC175 | 175 A DC Disconnect, Din Rail; |
03-77-008 |
MNDC250 | 250 A DC Disconnect, Din Rail |
Options |
||
03-77-009 |
MNEDC125 | 125 A Replacement Breaker, Stud, 125 VDC, 1 |
03-77-010 |
MNEDC175 | 175 A Replacement Breaker, Stud, 125 VDC, 1; |
03-77-011 |
MNEDC250 | 250 A Replacement Breaker, Stud, 125 VDC, 1 |
03-77-012 |
MNEPV30 | Din Rail Breaker, 30 A, 150 VDC; |
03-77-013; |
MNEPV50 | Din Rail Breaker, 50 A, 150 VDC |
03-77-014 |
MNEPV60 | Din Rail Breaker, 60 A, 150 VDC |
03-77-015 |
MNEPV63; | Din Rail Breaker, 63 A, 150 VDC |
03-77-016; |
MNTBB-NAKED | Bus Bar 4.63”, UL CSA Recognized. |
03-77-017 |
MNTBB-R-W | Insulated Bus Bar 4.63, UL ; CSA Recognized |
03-77-018 |
SHUNT-500 | Shunt, 500 A |
Transfer Switches
These relay-based automatic transfer switches provide
switching between two separate power sources.
Features include hard wire connections and durable
metal enclosure. It can be used in conjunction with
another transfer switch for additional power source
alternatives.
CSA and UL certified
# 08-19-011 30 A auto transfer switch
# 08-19-012 50 A auto transfer switch
# 08-19-013 100 A auto transfer switch
Generator Panel
This generator panel allows you to permanently connect a
standby power source to specific circuits, such as lighting,
heating, refrigerator, freezer, sump pump, etc.
Measures 22.5 x 32 x 9.5 cm
# 08-17-001 Eight circuit inverter bypass panel
Inverter Fuse Blocks
Our DC Fuse and Holder are extra heavy duty DC Class
"T" rated fuses from 110 to 400 A, with "slow blow"
characteristics suitable for inverter installations. Protect
yourself and your equipment! Includes mounting block,
fuse and protective cover. Screw lugs fit bare cable to 4/0.
| # 08-58-001 110 A # 08-58-002 200 A # 08-58-003 300 A # 08-58-004 400 A Options: # 08-16-137 F-110 replacement fuse # 08-16-138 F-200 replacement fuse # 08-16-139 F-300 replacement fuse # 08-16-140 F-400 replacement fuse |
|
||||||||||||||||||||||||||||||||||||
The information contained herein is subject to change without notice.
| Matrix Energy Inc. | info@matrixenergy.ca | Toll Free: 1-866-630-5630 |
























